The storage vault was located beneath the roadway, and consisted of a flat plate roof system, interior columns, and a raft type of foundation system. Construction was carried out in six different “segments”, producing a storage reservoir approximately 44m x 66m x 5m high. A flow restriction device and a control valve system were also included in the design to control the rate of outflow to the existing storm sewer after the storm has subsided.